Spectrophotometric Determination of Trace Tantalum with Phenylfluorone-tartaric-CTAB following the solvent extraction of Ta as Tri-iso-octylamine in benzene
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Trace tantalum can be quantitatively extracted into benzene with tri-iso- octylamine (TIOA) from aqueous solution of 0.4N HF-1.3 N HN03. The opti- mum conditions for Ta-phenylfluorone-tartaric-CTAB complex formation have been studied. The lower determination limit is approximately 0.025 ppm of Ta. ε=1.38 105. The calibration curve for Ta is linear within a range of 0-5 ug/10 ml.

    Reference
    Related
    Cited by
Get Citation

陈志澄,马自成,1983,三异辛胺萃取分离苯芴酮CTAB测定微量钽[J].岩石矿物学杂志,2(3):209~210.,1983,Spectrophotometric Determination of Trace Tantalum with Phenylfluorone-tartaric-CTAB following the solvent extraction of Ta as Tri-iso-octylamine in benzene[J]. Acta Petrologica et Mineralogica,2(3):209~210.