An accurate and highly sensitive spectrographic method for the determina tion of ultratrace gold was reported. This method was based on the use of a small activated carbon column for collecting gold. The quantity of the activa- ted carbon used in the column was so arranged that the weight of the ash formed after ignition was about 0.1-0.15mg. The ash was then subjected to spectro- graphic determination. This method can be applied in the concentration range of 0.1-3000 ppb of gold. The coefficient of variation of gold was 20-27% for geological materials containing O.x-xppb of gold. Calibration curve was linear in the range of 2 ng-30ng of gold. The detection limit was 1-2ng.
Reference
Related
Cited by
Get Citation
蒋建华,马重光,陈方伦,1982,化学光谱法测定超痕量的金[J].岩石矿物学杂志,1(2):48~52.,1982,Determination of Ultratrace of Gold by Chemical Spectrographic Method[J]. Acta Petrologica et Mineralogica,1(2):48~52.