The content of nickel oxide in neodymium oxide was determined by ICP-OES method. The content of nickel oxide was 0.002 7%. Various influencing factors in the detection process were analyzed. The reliability of the measurement results was expressed by relative expansion uncertainty (Urel=12%, k=2). The calculation of re-lative uncertainty component shows that the relative uncertainty component introduced by standard curve fitting is the largest, urel(c2)=5.639%, followed by the relative uncertainty component introduced by the preparation of standard solution, urel(c1)=0.879%. This paper can provide a reference of the result uncertainty analysis for relevant testing personnel.
参考文献
相似文献
引证文献
引用本文
朱小龙, 2022. 氧化钕中杂质氧化镍含量的测定及测量结果的不确定度分析[J]. 岩石矿物学杂志, 41(3):668~672. ZHU Xiao-long, 2022. Determination of nickel oxide content in neodymium oxide and its uncertainty analysis[J]. Acta Petrologica et Mineralogica, 41(3): 668~672.