Determination of Ga in Rocks by Flameless AAS Using Matrix Correction
Author:
Affiliation:
Fund Project:
摘要
|
图/表
|
访问统计
|
参考文献
|
相似文献
|
引证文献
|
资源附件
|
文章评论
摘要:
Abstract:
The matrix correction is suggested for determining Ga by flameless aas. The background is corrected by adding lmg/ml Ni using D2 lamp in 2 % nitric acid medium. The sensitivity of this method is 8.8 × 10-2g/1% Its C. V. for sample containing 0.02ppm of Ga is 1.81%(n=11).The re- coveries obtained by addition of standard Ga-solution are over 90 % . the mea- surable concentration range is O.OOOx-0.OOx % Ga.
参考文献
相似文献
引证文献
引用本文
秦忠骏,周剑林, 1984. 利用基体改进效应—无火焰原子吸收测定矿石中微量镓[J]. 岩石矿物学杂志, 3(4):367~370. , 1984. Determination of Ga in Rocks by Flameless AAS Using Matrix Correction[J]. Acta Petrologica et Mineralogica, 3(4): 367~370.